Your browser doesn't support javascript.
loading
Determination of Cilostazol in Human Plasma by HPLC / 中国药房
China Pharmacy ; (12)2005.
Article in Chinese | WPRIM | ID: wpr-525741
ABSTRACT

OBJECTIVE:

To establish a HPLC method for the determination of cilostazol in human plasma.

METHODS:

C18 was the chromatographic column,MeOH-0.03mol/L ammonium acetate (62∶38,V/V)was the mobile phase with a flow rate at 0.8 ml/min and detection wavelength at 257 nm,acetic ether was used as the extraction solvent.

RESULTS:

Good linear relationship was achieved when the detection concentration range of cilostazol was 10.0~1 500.0 ng/ml(r=0.9 999),the average recovery rates for the high,medium and low concentrations of cilostazol were 99.82%,97.30%and 97.14%,respectively,both the intra-day and inter-day RSD were lower than 6%.

CONCLUSION:

This method is sensitive,accurate,simple and fast,which can be used as the clinical monitoring of blood concentration of cilostazol and its pharmacokinetics study.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2005 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2005 Type: Article