Your browser doesn't support javascript.
loading
Comparison between Cuprophane and Polysulfone Membrane in Biocompatibility / 대한신장학회잡지
Korean Journal of Nephrology ; : 474-482, 2000.
Article in Korean | WPRIM | ID: wpr-52615
ABSTRACT

OBJECTIVE:

It has been proposed that the contact between blood and dialysis membrane during hemodialysis therapy induces harmful reactions to patients. Membrane biocompatibility is the characteristic that makes less adverse reaction. We tried to compare the biocompatibility between Cuprophane and Polysulfone membranes. MRTHODS Nine chronic renal failure patients who have undergone maintenance hemrodialysis therapy with Hemophan membrane three times per week were included in this study. Cuprophane membranes were used in the first week Hemophan membranes in the second week; Polysulfone membranes in the third week. Each membrane was used three times a week. On the day of third dialysis with the Cuprophane membrane(first week) and Polysulfone membrane(third week), serial blood sampling was obtained from the afferent line at hemodialysis initiation, 15 minutes, 30 minutes, 60 minutes, 120 minutes and 30 minutes to measure serum complement activity(C3a, C5a), blood polymorphonuclear leukocyte and platelet count, and arterial oxygen pressure which have been regarded as biocompatibility parameters. The parameters measured during the first week(Cuprophane) and the third week(Polysulfone) were compared to evaluate the difference in biocompatibility of both membranes.

RESULTS:

1) C3a desArg In both groups, the level of C3a desArg increased significantly from basal level and the Cuprophane group showed significantly higher level of C3a desArg than that of Polysulfone group. 2) C5a desArg In both groups, the level of C5a desArg did not increased sigpificantly from basal level. Only at 30 minute after hemodialysis, Cuprophane group showed significantly higher level of C5a desArg than that of Polysulfone group(p=0.037). 3) Polymorphonuclear leukocyte In both groups, the polymorphonuclear leukocyte counts decreased significantly at 15 minutes and 30 minutes from basal level. The polymorphonuclear leukocyte count was lower in Cuprophane group than that of Polysulfone group at 15 minute after hemodialysis(p=0.001). 4) Platelet In Cuprophane group, the platelet count was decreased significantly at 15 minute(p=0.004) but there were no difference in platelet counts between the two groups. 5) Arterial oxygen pressure Both group showed no consistent pattern of variation of oxygen pressure and there was no significant difference between the two groups.

CONCLUSION:

The biocompatibility of Polysulfone membrane was superior to the Cuprophane membrane with respect to the increased activation of complement C3a. decrease of polymorphonuclear leukocyte and decrease of platelet count.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Oxygen / Platelet Count / Blood Platelets / Complement System Proteins / Complement C3a / Renal Dialysis / Dialysis / Kidney Failure, Chronic / Membranes / Neutrophils Limits: Humans Language: Korean Journal: Korean Journal of Nephrology Year: 2000 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Oxygen / Platelet Count / Blood Platelets / Complement System Proteins / Complement C3a / Renal Dialysis / Dialysis / Kidney Failure, Chronic / Membranes / Neutrophils Limits: Humans Language: Korean Journal: Korean Journal of Nephrology Year: 2000 Type: Article