OBJECTIVE:

To establish a HPLC method for determining the content of fluvastatin sodium in fluvastatin sodium extended-release tablets.

METHODS:

An Agilent SB-C18 column was used and the mobile phase was CH3CN-0.1% phosphate acid, 50∶50. Flow rate was 1mL?min-1, wavelength was 234nm and the sample size was 20?L.

RESULTS:

The fluvastatin sodium concentration had good liner relationship from 4.84~96.8?g?mL-1(r=0.999 9), and the average recovery was 100.1%,RSD=0.9%.

CONCLUSION:

This method was simple, fast, accurate, and precise, could be used to determine content in fluvastatin sodium extended-release tablets.