Determination of Phospholipid Content in 5-FUR Prodrug Liposome / 中国药房
China Pharmacy
; (12)2001.
Article
in Zh
| WPRIM
| ID: wpr-530158
Responsible library:
WPRO
ABSTRACT
OBJECTIVE: To determine the concentration of phospholipid in 5-FUR prodrug liposome. METHODS: The sample was fragmented by ethanol and extracted by chloroform. The concentration of phospholipid in 5-FUR prodrug liposome was determined by ammonium ferrothiocyarate spectrophometry at a wavelength 488 nm. RESULTS: The linear range of phospholipid was 0.01~0.10 mg?mL-1(r=0.999 6, n=3) with an average recovery rate of 99.66% (RSD=3.17%). CONCLUSION: This method is simple, convenient and sensitive, and it can be used for the quality control of 5-FUR prodrug liposome.
Full text:
1
Index:
WPRIM
Language:
Zh
Journal:
China Pharmacy
Year:
2001
Type:
Article