Your browser doesn't support javascript.
loading
Determination of the Content of Main Components in Lipoic Acid Sustained-release Tablets by HPLC / 中国药房
China Pharmacy ; (12)2005.
Article in Chinese | WPRIM | ID: wpr-530784
ABSTRACT

OBJECTIVE:

To establish an HPLC method for the determination of lipoic acid in lipoic acid sustained-release tablets.

METHODS:

HPLC was conducted on a Hypersil ODS with acetonitrile-0.05 mol?mL-1 potassium dihydrogen phosphate(45∶55,adjust pH to 2.0)as mobile phase at a flow rate of 1.0 mL?min-1.The injection volume was 10 ?L;the detection wavelength was set at 219 nm and the column temperature was 25 ℃.

RESULTS:

The linear range of lipoic acid was 9.99~399.70 ?g?mL-1(r=0.999)with an average recovery rate of 99.17%(RSD=0.40%);the intra-day and inter-day RSD were all less than 2.6%.

CONCLUSION:

The method is simple and accurate,and suitable for the determination of the content of lipoic acid in lipoic acid sustained-release tablets.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2005 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2005 Type: Article