Your browser doesn't support javascript.
loading
Content Determination of Chlorhexidine Acetate in Daobian Suppository by RP-HPLC / 中国药房
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-532084
ABSTRACT

OBJECTIVE:

To establish a RP-HPLC method for the determination of the content of chlorhexidine acetate in daobian suppository.

METHODS:

The determination was performed on Diamonsil C_(18)column,The mobile phase consisted of acetonitrile-water-triethylamine(30700.5,with pH adjusted to 3.0 by phosphoric acid)at a flow rate of 1.0 mL?min~(-1),The detective wavelength was 260 nm,the sample size was 20?L and the column temperature was maintained at 30℃.

RESULTS:

The linear range of Chlorhexidine Acetate was 1.092~13.10?g?mL~(-1)(r=0.999 9)and its average recovery was 98.29%(RSD=2.16%,n=9).

CONCLUSIONS:

The method is simple and accurate,and it can be used for the determination of the content of chlorhexidine acetate in daobian suppository.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2001 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2001 Type: Article