Your browser doesn't support javascript.
loading
Improvement of the Determination Method of Main Component in Lincomycin Hydrochloride Eye Drops / 中国药房
China Pharmacy ; (12)2005.
Article in Chinese | WPRIM | ID: wpr-532678
ABSTRACT

OBJECTIVE:

To improve the determination method for lincomycin hydrochloride eye drops so as to eliminate the interference of the bacterial inhibitor ethylparaben on the content of the main component.

METHODS:

The determination was performed by HPLC with phosphoric buffer (pH 6.8)-methanol (40∶ 60) as the mobile phase replacing the mobile phase of borax buffer (pH6.0)-methanol (4∶6) recommend in state chemicals standard technique (Method A).The contents of ethylparaben-contained sample and ethylparaben-free sample determined by HPLC were compared with those determined by Method A.

RESULTS:

There was no significant difference in the content of ethylparaben-free sample between the two determination methods,but the content of ethylparaben-contained sample determined by Method A was higher than both the labeled amount and that determined by the improved method.

CONCLUSION:

The improved method is applicable for the content determination of lincomycin hydrochloride eye drops.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2005 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2005 Type: Article