Your browser doesn't support javascript.
loading
Assay of in Vitro Plasma Protein Binding Rate of Mangiferin in Rats / 中国药房
China Pharmacy ; (12)2007.
Article in Chinese | WPRIM | ID: wpr-533037
ABSTRACT

OBJECTIVE:

To study the assay method of in vitro plasma protein binding rate of mangiferin in rats.

METHODS:

The plasma samples which were added with internal standard(rutin)were deproteinized with acetonitrile and the supernatant was assayed by HPLC.The equilibrium dialysis was carried out to determine the plasma protein binding rate of mangiferin.

RESULTS:

The plasma protein binding rates of mangiferin at low,middle and high concentrations were(50.0?1.9)%,(45.2?2.0)% and(45.9?2.1)%,respectively.

CONCLUSION:

This assay method is sensitive,reproducible and simple,and it meets the requirement of analysis.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2007 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2007 Type: Article