Your browser doesn't support javascript.
loading
Determination of Concentration of Netilmicin Sulfate in Human Serum by Ion-pair RP-HPLC / 中国药房
China Pharmacy ; (12)2007.
Article in Chinese | WPRIM | ID: wpr-533259
ABSTRACT

OBJECTIVE:

To establish an ion-pair RP-HPLC method for determination of the concentration of netilmicin sulfate in human serum.

METHODS:

The determination was performed on Luna C18 column with column temperature set at 40℃;the mobile phase consisted of acetonitrile-water (15∶85,pH 2.0,containing 10 mmol?L-1 sodium heptanesulfonate) at a flow rate of 0.8 mL?min-1.The detection wavelength was set at 205 nm.

RESULTS:

The linear range of netilmicin was 2~20 mg?L-1(r=0.997 6) with a recovery rate of 93.66%~96.05%.The intra-day and inter-day RSD were both less than 10%,respectively.

CONCLUSION:

The method is sensitive and simple with accurate and reliable results,and it is able to satisfy the requirement for the determination of serum concentration of netilmicin.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2007 Type: Article

Similar