Your browser doesn't support javascript.
loading
Investigation and Analysis of Automatic Injection Drug Dispensing System in Inpatient Dispensary / 中国药房
China Pharmacy ; (12)1991.
Article in Chinese | WPRIM | ID: wpr-533309
ABSTRACT

OBJECTIVE:

To optimize drug for injection dispensing model in order to supply reference for popularity of automatic injection drug dispensing system(AIDDS) in inpatient dispensary.

METHODS:

Two kinds of drug dispensing model were adopted in five departments.In 10 working days before and after application of AIDDS,the time of drug dispensing flow needed was recorded.The time of every drug dispensing step needed for single patient was recorded and analyzed to evaluate the benefit of system.

RESULTS:

After application of AIDDS,the drug dispensing time for single patient reduced from 1.5~2.1 min to 0.45~0.80 min.The drug dispensing efficiency was improved significantly,the extent of which was in positive correlation to amount of patient demanding drug dispensing.

CONCLUSION:

The application of AIDDS speedups drug for injection dispensing,shortens dispensing time and saves human resource.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 1991 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 1991 Type: Article