Your browser doesn't support javascript.
loading
The Measurement and Evaluation of the Cardiac Pump Function in Rats / 西安交通大学学报(医学版)
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6)1982.
Article in Chinese | WPRIM | ID: wpr-534558
ABSTRACT
The method of measuring cardiac-pump function with electromagneticflowmeter was studied in rats. CI, SVI, AFV and dF/dt measured in 20 nor-mal rats were 227 + 7 ml/kg/min, 0. 50 ? 0. 0.2ml/kg, 3. 35 ? 0. 17ml/secand 167 ? 9 ml/sec~2, respectively. The physiological status of the modelwithin 60 minutes was stable, When volume loading was given, CI and SVI of normal rats were incr-eased by 183 ? 8% and 190 ? 9%, AFV and dF/dt also increased significantlywith less degree (83 ? 8% and 64 ? 5%). The comparision of the pump function indices of the normal and themyocardial infarcted rats showed that during volume loading, the changesof pump function and its response curve were helpful to assess the damageof cardiac function.
Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Xi'an Jiaotong University(Medical Sciences) Year: 1982 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Xi'an Jiaotong University(Medical Sciences) Year: 1982 Type: Article