Your browser doesn't support javascript.
loading
Spiral CT Diagnosis of Hypoxic Ischemic Encephalopathy in New Born(An Analysis of 114 Cases) / 实用放射学杂志
Journal of Practical Radiology ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-538762
ABSTRACT
Objective To evaluate spiral CT in the diagnosis of hypoxic ischemic encephalopathy (HIE) in new born.Methods 114 cases HIE were examined with spiral CT, CT findings were analyzed.Results Brain edema of difference degree was found in all cases,thirty cases were showd intracranial hemorrhage.Conclusion Spiral CT scan is helpful for evaluating brain injury with HIE.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: Journal of Practical Radiology Year: 1992 Type: Article