Analysis of the complications of interlocking intramedullary nail for treatment of tibial fracture / 中国矫形外科杂志
Orthopedic Journal of China ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-544126
ABSTRACT
[Objective]To explore the complications of tibial fracture treated with interlocking intramedullary nail.[Method]The full data of 785 cases of tibial fiacture treated with interlocking intramedullary nail were studied retrospectively.[Result]Mean follow-up period was 27 months (8~40months).There were some complications as follows infection rate was 2.7% (21 cases),fracture nonunion 1.5% (12 cases),fracture delayed union 6.8% (53 cases),fracture malunion 0.9% (7 cases),knee pain 6.8% (53 cases),nail broken 1.4% (ll cases),locking screw broken or drop out 2.2% (17 cases).[Conclusion]Proper manipulations,strict indications,and postoperative treatment are vital to prevent the complications.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Orthopedic Journal of China Year: 2006 Type: Article