Determination of Chlorite,Chlorate and Bromate in Drinking Water by Ion Chromatography / 环境与健康杂志
Journal of Environment and Health ; (12)2007.
Article in Chinese | WPRIM | ID: wpr-547750
ABSTRACT
Objective To develop an ion chromatography (IC) for simultaneous determination of chlorite,chlorate and bromate in drinking water. Methods The IC separation was carried out with the IonPAC AS23 column by using 4.5 mmol/L Na2CO3-0.8 mmol/L NaHCO3 at the flow rate of 1.0 ml/min. The injection volume was 250 ?l,the temperature of conductivity detector cell and column were 30 ℃ and 35 ℃,respectively. The pressure upon the bottle of mobile phase was 40 kPa. The current of auto-regenerating suppressor was 25 mA. Results The results showed that in the range of 0 to 1 000 mg/L, the calibration equation for chlorite was y=0.009 6+1.600 0 x (r=0.999 3),for bromate was y=0.003 2+3.184 7 x (r=0.999 9),for chlorate was y= 0.001 8+1.788 9 x(r=0.999 9).The detection limit of chlorite,chlorate and bromate were all 5 ?g/ L,the recovery rates were 89.0% -108.0% and the relative standard deviations (RSD) were 0.21%-2.70%. Conclusion The method is simple,fast,accurate, sensitive,little interference and is applicable to the simultaneous determination of chlorite,chlorate and bromate in drinking water.