ABSTRACT
The author studies dynamically the changes of the liver tissue reaction to various suture materials during the period 5-90 days in the 96 rats.From the result of comparative experimental sdudy of the effect on tissue reaction, we had found All suture materials produce an intense inflammatory reaction for approximately five days after implantation, thereafter the liver tissue reaction to various suture materials makes a great difference. The least reaction suture is the nylon, the lagest reaction suture is the chromic catgut, dacron and silk are between them.The good "hand" of dacron, which ties like silk, and the slight inflammatory reaction produced this polyester do much to recommened its use in the liver.
Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Academic Journal of Second Military Medical University Year: 1983 Type: Article