Objective To assess the efficacy and safety of transurethral bipolar plasmakinetic resection of benign prostatic hyperplasia (BPH). Methods A total of 45 cases of BPH were treated by transurethral bipolar plasmakinetic resection of prostate (PKRP) and were followed up for 3-10 months.Results The weight of the resected prostate was 28-105 g with an average of (47?16) g, the operation time was 15-120 min with an average of (50?12) min. No case needed blood transfusion during the operation and no transurethral resection syndrome occurred. The mean catheterization time was 4 d and the mean postoperative hospital stay was 7 d. Peak urine flow increased from (7.3?1.5) ml/s to (16.2?4. 4) ml/s and IPSS decreased from (27.6?1.3) to (5.8?1.0) in 3 months postoperatively. Conclusion Transurethral bipolar plasmakinetic resection of prostate is effective and safe with less complications.