Determination of Gentiopicroside in Urine by LC/MS/MS / 中药新药与临床药理
Article in Zh | WPRIM | ID: wpr-574480
Responsible library: WPRO
ABSTRACT
Objective To establish a HPLC/MS/MS method for the determinati on of gentiopicroside in human urine.Methods The urine sample was treated by solid-phase extraction with internal standard of caffeine;The RESCEK C8 colum n(150mm?2.1mm,5 ?m) was used as the analytical column with a mobilep hase consisting of methanol-10mmol? L-1 NH4AC buffer(pH=6.5)-acetonit rile(50∶40∶10,V/V),the flow rate was 0.2 mL? min-1;A triple quadruple tandem mass spectrometer was used as the detector,Electrospray ioniza tion source was applied and operated in positiveion mode.Gentiopicroside and caffeine were detected by monitoring the ion transition of m/z 374.1→ 195.2 and m/z 195.2→ 138.2 respectively.Results The linear range was 30~ 9000 ng?mL-1(r=0.9980) for gentiopicroside in human urine.The recovery was 91.10% ~ 9 6.21 %,The absolute recovery was 100.52% ~ 103.83%,The within-day and between-day precisions were less than 10 %.Conclusion The method is proved to be sensitive,accurate,rapid,specific.
Key words
Full text: 1 Index: WPRIM Language: Zh Journal: Traditional Chinese Drug Research & Clinical Pharmacology Year: 2000 Type: Article