Your browser doesn't support javascript.
loading
Determination of paeonol and cinnamaldehyde in Jiarong Tablet by HPLC / 中成药
Chinese Traditional Patent Medicine ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-575547
ABSTRACT

AIM:

To establish an HPLC method of determining paeonol and cinnamaldehyde in Jiarong Tablet.

METHODS:

ColumnKromasil C_(18)(200 mm?4.6 mm I.D,5 ?m);mobile phaseMeOH-H_2O(65∶35);detection wavelength was at 288 nm;flow rate was 1.0 mL/min.

RESULTS:

The calibration curve showed a good linea-rity within the ranges of 0.003 6830.018 412 ?g for cinnamaldehyde,0.097 92-0.489 6 ?g for paeonol.(

CONCLUSION:

)The method is accurate and can be used for the quality control of Jiarong Tablet.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Traditional Patent Medicine Year: 1992 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Traditional Patent Medicine Year: 1992 Type: Article