ABSTRACT
Objective To evaluate the effectiveness and safety of transcatheter closure of membranous ventricular septal defect (MVSD) using Amplatzer membranous VSD occluder (AMVSO). Methods The patients, who were clinically diagnosed with VSD were recommended for further transthoracic echocardiographic assessment using multiple standard views. If there were left to right shunts across ventricular septum, the margin of defects to the aortic valve was more than 1mm and that to tricuspid valve was more than 3 mm. If there was an aneurysm, it should not interfere with the function of outlet of right ventricule. Finally, if the diameter of VSDs wasless than 14mm, catheter closure of VSDs was suggested in these patients. The patients, having residual shunt after surgical closure of VSD, were included. All procedures were performed under local or general anesthesia. Transthorac echocardiography and X ray were used continuously to monitor the procedure. Transthoracic echocardiography was performed immediately after the release of devices, 24 hours, and 3 months after the procedure, respectively.Results From June 2002 to March 2003, 32 consecutive patients (15 females), underwent transcatheter closure of MVSD. The mean diameters of VSDs measured by echocardiography was 5.1 mm (3~8 mm) and, while that by angiography was 4.4 mm (3~8 mm). The mean size of the occluder was 7.6 mm(4~12 mm). The successful rate of device implantation was 100% (32/32). The residual shunt immediately after the closure was 11.5%, whereas after 24 hours it was only 7.7%, which was not serious. After 3 months′ follow-up, only 3.8% trivial residual shunt existed. No death occurred during and after the procedure. Atrial tachycardia, ventricular tachycardia, and bundle (right and left bundle) branch block, which was considered to relate to catheter manipulation inside the chamber of ventricle, were common and transient. One aortic regurgitation and tricuspid insufficiency became severe after the procedure, but they were not serious. One patient developed III degree A-V block 24 hours after the procedure, and EKG became LBBB 3 days after the temporary pace making. Hemolysis was observed in one patient, and he recovered 7days after the medication therapy. Conclusion Transthoracic echocardiography was very much effective in catheter closure of MVSD. The asymmetric self-expanding nitinol double-disc Amplatzer device designed for the transcatheter closure of MVSD is implanted easily and stably. Due to low ratio of residual shunt and few serious complications, the Amplatzer device is a good choice for the transcatheter closure of MVSD.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Interventional Cardiology Year: 1996 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Interventional Cardiology Year: 1996 Type: Article