Significance of Hemoglobin Detection Test Kit Using in Hospital Supply Center / 中华医院感染学杂志
Chinese Journal of Nosocomiology
;
(24)2006.
Article
in Chinese
| WPRIM
| ID: wpr-594663
ABSTRACT
OBJECTIVE To compare the difference of testing cleaning effectiveness in the operation instrument between the eye measurement and hemoglobin enzyme test.METHODS Five batches of instrument after cleaning were tested by two methods.RESULTS By eye inspection,all tested samples were qualified.However there were only 76 percent of samples qualified according to enzyme test.CONCLUSIONS Compared with eye inspection,enzyme test is a more sensitive method.Enzyme test can better assess the cleaning effectiveness than others.
Full text:
Available
Index:
WPRIM (Western Pacific)
Type of study:
Diagnostic study
Language:
Chinese
Journal:
Chinese Journal of Nosocomiology
Year:
2006
Type:
Article
Similar
MEDLINE
...
LILACS
LIS