ABSTRACT
Objective To evaluate the value of magnetic resonance cholangiopancreatography(MRCP) in the diagnosis of biliary obstruction diseases by comparison with endoscopic retrograde cholangiopancreatography (ER-CP). Methods A total of 36 patients with biliary obstruction diseases underwent both MRCP and ERCP. To review the images obtained from ERCP and MRCP ,the diagnosis were compared according to pathology. MRCP and ERCP in the diagnosis and treatment of biliary obstruction disease were analysed. Results 36 patients including 16 biliary tumors, 15 cholelithiases,and five other diseases were analysed. The diagnosis accuracy of MRCP and ERCP for bil-iary obstruction diseases were 86.1% and 91.7 %, there was no significant difference( P > 0.05). Conclusion MR-CP can accurately define the obstructively sites, identify the obstructive causes and is a noninvasive and reliable exam-ination for biliary obstruction diseases.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: Chinese Journal of Primary Medicine and Pharmacy Year: 2008 Type: Article