Analysis of causes of pediatric bronchoscopy-induced complications and the nursing measures / 现代临床护理
Modern Clinical Nursing ; (6): 19-20,21, 2015.
Article in Chinese | WPRIM | ID: wpr-601489
ABSTRACT
Objective To analyze the causes of complications by pediatric fiberoptic bronchoscopy and find out the nursing measures. Method The clinical data of 60 children undergoing fiberoptic bronchoscopy were reviewed to analyze the causes of complications and concluded the nursing measures. Result Twelve in the sixty children contracted complications, including 4 cases of cyanotic , 4 cases of throat injury and 2 cases of laryngeal spasm . Conclusion Such measures as psychological nursing before operation to the children and their families for their cooperation, intraoperative oxygen suction, quick clinical examination, avoidance of frequent negative pressure suction and close observation of complications are of great importance for preventing complications induced by fiberoptic bronchoscopy.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Etiology study Language: Chinese Journal: Modern Clinical Nursing Year: 2015 Type: Article