Your browser doesn't support javascript.
loading
Evaluation on measurement uncertainty of blood routine examination / 国际检验医学杂志
International Journal of Laboratory Medicine ; (12): 3232-3234,3237, 2015.
Article in Chinese | WPRIM | ID: wpr-602610
ABSTRACT
Objective To explore the feasibility of measurement uncertainty in complete blood count using internal quality con-trol(IQC) data associated with Sysmex Network Communication System(SNCS) comparative data .Methods Complete blood count assay including white blood cell(WBC) count ,red blood cell(RBC) count ,hemoglobin(Hb) determination ,hematocrit(HCT) values and platelet(PLT) count were involved to evaluate measurement uncertainty according to the instruction of CNAS-TRL-001 .Meas-urement uncertainty evaluation was established by internal measurement reproducibility using IQC data ,and standard measurement uncertainty by bias using proficiency testing(PT) data and SNCS data ,followed by relative combined standard measurement uncer-tainty and relative expanded measurement uncertainty was calculated .Meanwhile ,the measurement uncertainty was compared by u-sing PT data and SNAS comparative data .Results Relative expanded measurement uncertainty of the above mentioned index by u-sing IQC data associated with PT data was the followingWBC(10 .02% ,7 .24% ,7 .04% ,from level 1 to level 3 respectively) ,RBC (2 .40% ,1 .72% ,1 .92% ,from level 1 to level 3 respectively) ,Hb(3 .54% ,2 .56% ,2 .50% ,from level 1 to level 3 respectively) , HCT(4 .12% ,3 .18% ,2 .86% ,from level 1 to level 3 respectively) ,PLT(15 .36% ,8 .86% ,7 .94% ,from level 1 to level 3 respec-tively) .Relative expanded measurement uncertainty of the above mentioned index by using IQC data associated with SNCS compar-ative data was the followingWBC(11 .66% ,7 .34% ,6 .40% ,from level 1 to level 3 respectively) ,RBC(2 .26% ,1 .60% ,1 .64%from level 1 to level 3 respectively) ,Hb(3 .36% ,2 .36% ,2 .10% ,from level 1 to level 3 respectively) ,HCT (3 .36% ,3 .04% , 3 .18% ,from level 1 to level 3 respectively) ,PLT (13 .34% ,8 .36% ,7 .14% ,from level 1 to level 3 respectively) .Conclusion Measurement uncertainty in complete blood cell could be estimated by using IQC data associated with SNCS comparative data , which is in accord with the instrument of target measurement uncertainty .

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: International Journal of Laboratory Medicine Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: International Journal of Laboratory Medicine Year: 2015 Type: Article