Your browser doesn't support javascript.
loading
Content Determination of Phosphatidylcholine in Eustachian Tube Lavage Fluid of Patients with Secretory Otitis Media by HPLC / 中国药房
China Pharmacy ; (12): 2989-2990,2991, 2015.
Article in Chinese | WPRIM | ID: wpr-605077
ABSTRACT

OBJECTIVE:

To establish a method for content determination of phosphatidylcholine in eustachian tube lavage fluid of patients with secretory otitis media.

METHODS:

HPLC was used. The samples were pretreated by liquid-liquid extraction. It was performed on the column of Hypersil CN with mobile phase of acetoneitril-methanol-phosphoric acid (100∶10∶0.6,V/V/V)at the flow rate of 1.8 ml/min,the detection wavelength was 205 nm,temperature was 30 ℃ and volume was 20 μl.

RESULTS:

The lin-ear range of phosphatidylcholine was 11.99-119.9 μg/ml(r=0.999 6);RSDs of precision tests of intra-day and inter-day were no more than 15%;average recovery was 97.54%(RSD=9.36%,n=9);the average content of phosphatidylcholine in eustachian tube lavage fluid of patients was(24.43±3.61)μg/ml.

CONCLUSIONS:

The method is simple and accurate,and can be used for the content determination of phosphatidylcholine in eustachian tube lavage fluid of patients with secretory otitis media.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2015 Type: Article