ABSTRACT

OBJECTIVE:

To observe the efficacy and safety of carboprost and Foley catheter for the expand cervix before hys-teroscopic electric resection.

METHODS:

80 patients with hysteroscopic operation were randomly divided into research group and control group. Research group was placed inside the vagina carboprost 1 mg 30 minutes before operation;control group was placed inside the Foley catheter 12 hour before operation. The relaxation degree of the cervix,average operative time,preoperative pain, postoperative morbidity and incidence of adverse reactions in 2 groups were observed.

RESULTS:

There were no significant differ-ences in the relaxation degree of the cervix,postoperative morbidity and incidence of adverse reactions between 2 groups(P>0.05). The average operative time and preoperative pain in research group were significantly better than control group,the differ-ence was statistically significant(P<0.05).

CONCLUSIONS:

Carboprost and Foley catheter have good efficacy and safety for ex-pand cervix before hysteroscopic electric resection,however,carboprost is better than Foley catheter in terms of average operative time and preoperative pain.