Your browser doesn't support javascript.
loading
Determination of Residual Organic Solvents in Piperazine Ferulate by GC / 中国药师
China Pharmacist ; (12): 166-168,169, 2017.
Article in Chinese | WPRIM | ID: wpr-606098
ABSTRACT

Objective:

To establish a method for the determination of benzene, chlorine alcohol and pyridine residues in piperazine ferulate.

Methods:

GC was used with a DB-624 (30 m × 0. 53 mm, 1. 0 μm) elastic quartz capillary column. The flame ionization detector was used with nitrogen as the carrier gas. The initial temperature was 50℃, maintaining for 5 min, and raised to 80℃ at the rate of 10℃·min-1 , and then raised to 200℃ at the rate of 50℃·min-1 , and maintaining for 4 minutes. The inlet temperature was 200℃, and the detector temperature was 220℃. The split ratio was 1 ∶1 and the injection volume was 1μl. The flow rate was 3 ml· min-1.

Results:

The linear range of benzene was 0.16-0.96 μg·ml-1(r=0.999 5), the average recovery was 95.7% (RSD =2.1, n=9), and the detection limit was 0.16 ng. The linear range of chlorine alcohol was 16.11-96.65 μg·ml-1(r=0.999 7), the average recovery was 97. 8% (RSD=2. 1, n=9), and the detection limit was 0. 62 ng. The linear range of pyridine was 15. 87-95. 23 μg·ml-1(r=0. 999 8), the average recovery was 99. 2% (RSD=1. 3, n=9), and the detection limit was 0. 15 ng. Con-clusionThe method is reliable, simple, accurate and stable, and suitable for the determination of benzene, chlorine alcohol and pyri-dine residues in piperazine ferulate.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacist Year: 2017 Type: Article

Similar

MEDLINE

...
LILACS

LIS