ABSTRACT

Objective:

To establish a method for the content determination of magnesium in esomeprazole magnesium.

Methods:

The content of magnesium in esomeprazole magnesium was determined by inductive coupled plasma atomic emission spectrometry. Re-sultsThe linear range was 10.0-80.0 μg·ml-1(r=0.999 8). The average recovery was 99.55% with RSD of 1.35% (n=9). The detection limit was 0. 000 75 μg·ml-1 and the quantitative limit was 0. 002 5 μg·ml-1 .

Conclusion:

The method is accurate, sensitive and reproducible, which can be used for the content determination of magnesium in esomeprazole magnesium.