Objective To discuss the changes of the quality of the fresh frozen plasma,which leaved refrigerator and it was out of the cold chain.Method The fresh frozen plasma was placed at the room temperature,in six different periods,that is 0,0.5,2,4 h,8,and 12 hours.The prothrombin time,activated partial thrombin live enzymes time,fibrinogen and factor FⅤ,factor FⅧ,antithrombin(AT) and protein C were tested on each point.Results In the fourth group and the fifth group,the FⅧ,AT,and protein C were statistically lower compared with the controls (P<0.05).But there were no obvious changes of APTT,PT,INR,Fbg and FⅤwhen placed at room temperature for 12 hours.Conclusion After the fresh frozen plasma placed at room temperature for more than 8 hours,the FⅧ ∶ C,AT and protein C were significantly lower compared with the control group.But they have no obvious changes of APTT,PT,INR,Fbg and F Ⅴ when placed at room temperature for 12 hours.