Your browser doesn't support javascript.
loading
The technical investigation of 3.0T multi-modal quantitative MR imaging in rabbit liver / 实用放射学杂志
Journal of Practical Radiology ; (12): 644-647, 2017.
Article in Chinese | WPRIM | ID: wpr-608995
ABSTRACT
Objective To investigate the technical requirements for the 3.0T multi-modal quantitative MR imaging of the rabbit liver.Methods A total of 8 rabbits were scanned and T1 mapping,T2 mapping,MT and Gd EOB-DTPA dynamic enhancement images were acquired.For the dynamic enhanced scanning,injecting contrast medium was followed by saline flush with different combinations of injection flow rate (1.5 mL/s and 2 mL/s) and injection volume(6 mL and 8 mL).The quality of the images was assessed and analyzed statistically.Results The total scanning time was about 20-25 min.High-quality images were acquired by T1 mapping,T2 mapping and MT sequences.There was no significant difference in image quality among different groups in Gd-EOB-DTPA dynamic enhanced scanning(P>0.05).Two rabbits died when the combination of injection flow rate of 2 mL/s and injection volume of 8 mL was used.Conclusion 3.0 T multi-modal quantitative MR scanning of rabbit liver can be achieved successfully if scanning parameters are properly chosen.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Practical Radiology Year: 2017 Type: Article