Your browser doesn't support javascript.
loading
Ultrasonic Characteristics of Complex Fibroadenoma of Breast and Its Differential Diagnosis from Invasive Ductal Carcinoma / 中国医学影像学杂志
Article in Zh | WPRIM | ID: wpr-609153
Responsible library: WPRO
ABSTRACT
Purpose To explore ultrasonic characteristics of complex fibroadenoma (CF) of breast and its differential diagnosis from invasive ductal carcinoma (IDC).Materials and Methods Sixty-one patients with CF and 81 patients with IDC from January 2010 to February 2016 in the Affiliated Union Hospital of Fujian Medical University were enrolled,and the CF and IDC were confirmed by pathology after operation.The preoperative sonographic findings of CF and IDC were retrospectively analyzed and compared.Results Fifty-nine cases with CF were detected by ultrasonography in 61 cases.Ultrasonic findings of 59 cases of CF showed as follows:79.7% (47/59) of the CF cases with an aspect ratio <0.7;79.7% (47/59) with blood flow signal of 0 to 1 level;72.9% (43/59) with liquid dark area,including 67.8% (40/59) with round or oval cystic fluid area showing local sievelike or diffused distribution;72.9% (43/59) with irregular shape;61.0% (36/59) with obscure boundary;61.0% (36/59) with the largest diameter of tumor <2 cm;59.3% (35/59) with calcifications,including 33.9% (20/59) with coarse calcification,25.4% (15/59) with microcalcification and 85.7% (30/35) with distribution of calcified lesions along the linear high echo zone;54.2% (32/59) with echo heterogenicity showing linear high echo and high echo in the middle and low echo.There were significant differences in the detection rates of internal regular fluid area,internal linear high echo or high echo area,and alcification distribution along the linear high echo between CF and IDC lesions (all P<0.01).Compared with IDC,there were higher rates in CF for detecting lesions of largest diameter of tumor <2 cm,more regular shape,more clear border,poorer blood flow signal (P<0.05),but there were lower rates in CF for detecting axillary lymph node enlargement,lesions with edge or spiculation and hyperechoic halo (P<0.01).Conclusion Color Doppler ultrasonography is of great value in the diagnosis of CF and its differential diagnosis from IDC.
Key words
Full text: 1 Index: WPRIM Type of study: Diagnostic_studies Language: Zh Journal: Chinese Journal of Medical Imaging Year: 2017 Type: Article
Full text: 1 Index: WPRIM Type of study: Diagnostic_studies Language: Zh Journal: Chinese Journal of Medical Imaging Year: 2017 Type: Article