Study on colorectal distension with partially automated and individualized insufflation of air for dual-energy CT colonography / 重庆医学
Chongqing Medicine ; (36): 1897-1899,1903, 2017.
Article in Chinese | WPRIM | ID: wpr-610015
ABSTRACT
Objective To study the compliance of examinees,and effectiveness of colorectal distension with partially automated and individualized insufflation of air for dual-energy CT colonography.Methods Forty-six healthy adult volunteers without history of conditions affecting gastrointestinal motor function were enrolled in this study.One day before CT examination,volunteers were asked to orally administered 60 mL 4% diatrizoate meglumine five times for fecal tagging.Air was insufflated by using an inflator in a partially automated and individualized manner.The volunteers were initially asked to assume the right lateral decubitus position,then slowly turn to the supine position.Insufflation rate began at 1.5 L/min,and decreased to 0.5 L/min at later stage.The necessity and volume of air insufflation were decided according to effectiveness of colorectal distension on CT scout images,self-reported sensation of volunteers,and intestinal pressure.Dual-energy CT scanning was performed,and dual-energy blended images were acquired.Compliance of volunteers was statistically analyzed.The effectiveness of colorectal segments distension was statistically analyzed by using Kruskal-Wallis H test.Results No abdominal pain,bloating,nausea or vomiting were noted in the 46 volunteers.All volunteers easily accepted colorectal insufflation of air,with grade 1 compliance.The effectiveness of colorectal distension of grades 1,2,3 and 4 were 0%,2.1%,5.1% and 92.8%,respectively.The difference of effectiveness of colorectal segments distension had no statistical significance(χ2=6.19,P=0.288).The effectiveness of insufflation was poor in 6 colorectal segments,including 2 in sigmoid colon and 2 in rectum.Effectiveness of insufflation was suboptimal in 14 colorectal segments,including 4 in descending colon,4 in sigmoid colon,and 3 in rectum.Conclusion Compliance of examinees with partially automated and individualized insufflation of air for dual-energy CT colonography is excellent,with good effectiveness of colorectal distension.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chongqing Medicine Year: 2017 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chongqing Medicine Year: 2017 Type: Article