Your browser doesn't support javascript.
loading
Application of computer-assisted pre-operation plan for the treatment of geriatric intertrochanteric femoral fractures / 中华骨科杂志
Chinese Journal of Orthopaedics ; (12): 1061-1068, 2017.
Article in Chinese | WPRIM | ID: wpr-611161
ABSTRACT
Objective To discuss the curative effect of computer assisted pre-operation plan (CAPP) in treating the geriatric intertrochanteric femoral fracture.Methods The data of intertrochanteric fractures treated with PFNA-Ⅱ between March 2012 and June 2015 were retrospectively analyzed.They were divided into two groups by preoperative design.One group was the CAPP group consisting of 53 patients with a mean age of 75.3 years (range,60-92 years).According to the Evans Classification,there were 12 Evans type Ⅰb,9 Evans type Ⅰc,15 Evans type Ⅰd and 17 Evans type Ⅱ fractures.The other group was the non-CAPP group consisting of 74 patients with a mean age of 76.6 years (range,62-95 years).There were 18 Evans type Ⅰb,15 Evans type Ⅰc,20 Evans type Ⅰd and 21 Evans type Ⅱ fractures.Operation time,intraoperative blood loss,times of fluoroscopy during operation and days of hospital stay were compared.The hip joint function was evaluated by Harris score at the final follow-up.Results The CAPP meanly cost 24.7 min.The consistency of the surgery and CAPP was up to 100%.In the CAPP group,the average operation time was 46.8±6.5 min;the average times of fluoroscopy during operation were 12.0±2.3 times;and the average blood loss was 154.4±27.6 ml.In the non-CAPP group,the average operation time was 57.8±10.3 min;the average times of fluoroscopy during operation was 20.9±3.2;and the average blood loss was 235.0±65.8 ml.All above data in the CAPP group were significantly lower than those in the non-CAPP group.The mean days of hospital stay were 13.9±1.3 days in the CAPP group and 14.3±1.4 days in non-CAPP group.The days of hospital stay had no significant difference between the two groups.Forty-five patients with an average follow-up period of 18.3 months were reviewed in the CAPP group.Fifty patients were followed up with an average period of 19.2 months in the non-CAPP group.At the final follow-up,the average Harris score was 88.6±2.8 points (range,84-96 points) in the CAPP group and 87.5±3.2 points (range,80-95 points) in the non-CAPP group.Conclusion CAPP system is convenient and efficient.It can facilitate the treatment of intertrochanteric fracture effectively.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Orthopaedics Year: 2017 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Orthopaedics Year: 2017 Type: Article