Application of rotary cutter during laparoscopic splenectomy / 中国内镜杂志
China Journal of Endoscopy
;
(12): 96-98, 2017.
Article
in Chinese
| WPRIM
| ID: wpr-612192
ABSTRACT
Objective To explore the feasibility and clinical effects of rotary cutter in laparoscopic splenectomy in treatment of traumatic spleen rupture.Methods The study retrospectively identified 10 cases with traumatic spleen rupture treated with laparoscopic splenectomy from June 2014 to June 2016.Results Total laparoscopic splenectomy combined with rotary cutter was completed successfully in 9 cases and 1 case was converted to open laparotomy due to intraoperative uncontrollable hemorrhage. The former operative time was 95 ~ 170 min, the estimated intraoperative amount of blood loss was 300 ~ 800 ml and autologous blood transfusion of 400 ~ 1 200 ml was conducted. The postoperative hospital stay was 8 ~ 14 d. No serious complications were found in the cases followed-up for 3 ~ 24 months after operation.Conclusion Laparoscopic splenectomy combined with rotary cutter is not only feasible and safe but also has the merits of minimally invasive surgery. It can be applied in treating those with abdominal trauma and with benign lesions in spleen. So it deserved promotion and application in clinical work.
Full text:
Available
Index:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
China Journal of Endoscopy
Year:
2017
Type:
Article
Similar
MEDLINE
...
LILACS
LIS