Your browser doesn't support javascript.
loading
Interfractional dosimetric study of target volume and organs at risk following intracavitary brachytherapy for cervical cancer / 中华放射肿瘤学杂志
Chinese Journal of Radiation Oncology ; (6): 1045-1049, 2017.
Article in Chinese | WPRIM | ID: wpr-613016
ABSTRACT
Objective To examine the interfractional dosimetric variations among inverse three-dimensional (3D) plan, forward 3D plan, and two-dimensional (2D) plan of intracavitary brachytherapy for cervical cancer, and to discuss the risk of implementing the interval plan on different implantation applicators at short time intervals.Methods Twenty-five groups of CT-guided intracavitary brachytherapy (two consecutive radiations at ≤4 d apart) plans from 11 cervical cancer patients who received radical radiation therapy in our hospital were reviewed and compared.The dwelling location and time of the first intracavitary brachytherapy plan (Plan-1) were simulated on the CT image of the second intracavitary brachytherapy to form Plan-1-S.The target coverage indices and D 2 cc of organs at risk (OARs) of Plan-1-S and Plan 2(actual plan of the second intracavitary brachytherapy) under the three planning modes were recorded and compared using the paired t-test, Wilcoxon signed rank test, and ANOVA.Results The D90, D100, and V100 of high-risk CTV were significantly lower in Plan-1-S created under the inverse mode in the actual plan (-9.11±13.46%,-13.16±18.79%, and-7.80±13.34%, P=0.002, 0.002, and 0.005, respectively).D90, D100, and V100 of the interval plan had the greatest reduction under the inverse mode (76%, 80%, and 76%, respectively).The maximum reductions in D90, D100, and V100 were 332.14 cGy (2D), 244.12 cGy (forward), and 41.76%(inverse).OAR overdose occurred most frequently under the forward mode;the rates of D90, D100, and V100 reductions accompanied by one OAR overdose were 29.41%, 37.50%, and 25.00%, and the rates of D90, D100, and V100 reductions by two OAR overdoses were 5.88%, 12.50%, and 6.25%,respectively.Overdose occurred most frequently in the small intestine (36%).Comparison of the three planning modes showed that the inverse plan had a greater reduction in each target coverage index than the 2D plan.Conclusions The simulated interval plan can significantly reduce target coverage and increase the risk of OAR overdose regardless of the planning mode and the short time intervals, and is therefore not recommended for clinical application.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Etiology study Language: Chinese Journal: Chinese Journal of Radiation Oncology Year: 2017 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Etiology study Language: Chinese Journal: Chinese Journal of Radiation Oncology Year: 2017 Type: Article