Your browser doesn't support javascript.
loading
Method for measuring different range of iodine concentration in drinking water by arsenic cerium catalytic spectrophotometry / 中华地方病学杂志
Chinese Journal of Endemiology ; (12): 537-541, 2017.
Article in Chinese | WPRIM | ID: wpr-617990
ABSTRACT
Objective To establish a catalytic spectrophotometric method for determination of iodine in water using the same arsenious acid solution and ceric ammonium sulfate solution as those used in the 2016 version standard method for determination of urinary iodine,and to meet the needs of wide concentration range of water iodine detection.Methods After pretreatment of the water sample with the effective chlorine of sodium dichloroisocyanurate solution for eliminating the interference of reducing substances at room temperature,the concentration of iodine in water was determined by arsenic cerium catalytic spectrophotometry using the same 0.025 mol/L arsenious acid solution and 0.025 mol/L ceric ammonium sulfate solution as those used in the 2016 version standard method for determination of urinary iodine.The linear relationship of the standard curve and the linear rang of different iodine concentration range (0-100,0-400,0-800μg/L),the detection limit,the precision and the accuracy of the sample were tested.Results The calibration relation of C =a + blgA (Ciodine concentration,Ameasuring absorbance) in the new method existed when arsenic cerium catalytic reaction was kept at a certain stable temperature ranging from 15 ℃ to 30 ℃ in certain stable reacting time.The linear correlative coefficients absolute value of different iodine concentration range (0-100,0-400,0-800 μg/L) were all greater than 0.999 0,corresponding to the water iodine detection limits were 0.3 μ,g/L (sample volume of 0.80 ml),1.2 μg/L (sample volume of 0.20 ml),and 2.2.μg/L (sample volume of 0.10 ml),respectively.The coefficients of variation (CV) of the three different iodine concentration range were all below 1.0% (n =6).The iodine recovery rate range of a total of 10 different water samples in these three different concentration range was 95.8%-98.7%,98.3%-103.7% and 98.5%-104.5%,and the average recovery rate was 97.6%,100.4% and 102.4%,respectively.In the range of these three different standard curves,water iodine standard materials GBW09114c,GBW09114a and GBW09113c were measured.The relative errors between the results and the given values were < 3.0%,which were in the range of uncertainty of the given value.Conclusion This method verified by methodology experiments has wide linear range,high precision,accuracy,and anti-interference ability,good reproducibility,and is easy to operate,with reduced amount of arsenic waste,reduced environmental pollution,and is suitable for application in different areas to determine water iodine.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Endemiology Year: 2017 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Endemiology Year: 2017 Type: Article