Consistency of TEE technique and PAC method in monitoring cardiac volume load and cardiac hemodynamic changes / 心血管康复医学杂志
Chinese Journal of cardiovascular Rehabilitation Medicine
;
(6): 328-331, 2017.
Article
in Chinese
| WPRIM
| ID: wpr-618351
ABSTRACT
Objective:
To evaluate the consistency of transesophageal echocardiography (TEE) and pulmonary artery catheter (PAC) method in monitoring cardiac volume load and cardiac hemodynamic indexes.Methods:
A total of 45 patients undergoing coronary artery bypass grafting in our hospital were selected.The right ventricular end-diastolic volume (RVEDV), right ventricular end-systolic volume (RVESV) and right ventricular ejection fraction (RVEF) were monitored during surgery by TEE and PAC respectively.Consistency of monitored data was compared between two methods.Results:
Both TEE and PAC indicated that compared with baseline level, after loading, there were significant rise in RVEDV [TEE (38±6)ml vs.(51±9ml), PAC (153±17)ml vs.(188±19)ml], RVESV [TEE (19±4)ml vs.(33±5)ml, PAC (92±16)ml vs.(110±23)ml], P0.05.Before therapy, RVEDV, RVESV and RVEF monitored by PAC and TEE showed significant positive correlation, and all relevant coefficients were >0.8 (r=0.844, 0.862, 0.916, P0.8 (r=0.892, P<0.01).Conclusion:
In clinical monitor, the consistency of TEE and PAC is high,the former is non-traumatic,and is more convenient for clinical use.
Full text:
Available
Index:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
Chinese Journal of cardiovascular Rehabilitation Medicine
Year:
2017
Type:
Article
Similar
MEDLINE
...
LILACS
LIS