Your browser doesn't support javascript.
loading
The application of hypothermic perfusion via renal artery balloon catheter in laparoscopic partial nephrectomy / 介入放射学杂志
Journal of Interventional Radiology ; (12): 413-417, 2017.
Article in Chinese | WPRIM | ID: wpr-619331
ABSTRACT
Objective To evaluate the feasibility and safety of hypothermic perfusion via renal artery balloon catheter before laparoscopic partial nephrectomy.Methods A total of 35 patients,who were arranged to receive laparoscopic partial nephrectomy during the period from March 2013 to December 2016 at the General Hospital of PLA,China,were enrolled in this study.The tumor was located in the left kidney in 22 patients and in the right kidney in 13 patients.The long diameter of the tumors was 2.3-7.0 cm,with a mean of (4.1±1.2) cm.Before laparoscopic partial nephrectomy,the implantation of renal artery balloon catheter was performed in all patients.The intraoperative renal cold-ischemia time,the time spent for operation and the amount of intraoperative blood loss were recorded.The creatinine clearance rate (Ccr) and estimated glomerular filtration rate (eGFR) were determined before operation as well as at one,3 and 7 days after operation.The intraoperative and postoperative complications were analyzed.Results Successful implantation of renal artery balloon catheter was accomplished in all 35 patients,with the technical success rate being 100%.Slipping of balloon catheter before laparoscopic partial nephrectomy occurred in one patient;in 2 patients incomplete occlusion of renal artery was found during operation and artery forceps had to be used to occlude the renal artery.In the other 32 patients,laparoscopic partial nephrectomy under the condition of hypothermic perfusion via renal artery balloon catheter was successfully carried out.No severe complications occurred during and after the operation.The average cold-ischemia time of the diseased kidney was 45 (20-125) min,the mean time for interventional procedure was 28 (20-40) min,the average surgery time was 147(95-235) min,the average amount of intraoperative blood loss was 180(50-1000) ml.The Ccr values determined before and at one,3,7 days after nephrectomy were (96.5±15.1),(75.2±10.5),(54.3±13.8) and (91.8±14.1) ml/min respectively.The eGFR values determined before and at one,3,7 days after nephrectomy were (99.5±15.3),(70.3±12.5),(65.5±11.7) and (96.8±12.3) ml·min-1·m-2 respectively.Statistical analysis indicated that in both groups the preoperative and 7-day postoperative Ccr values and eGFR values were significantly different from their one-day and 3-day postoperative values (P<0.01),but no statistically significant differences existed between preoperative values and 7-day postoperative ones (P>0.05).Conclusion Hypothermic perfusion via renal artery balloon catheter before laparoscopic partial nephrectomy is clinically safe and feasible,it can prolong the safe time of renal ischemia and protect renal function.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Interventional Radiology Year: 2017 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Interventional Radiology Year: 2017 Type: Article