ABSTRACT
Objective To introduce improved program for traction wire production in endoscopic submucosal dis-section assisted by oral traction. Methods A retrospective analysis was performed on 40 patients who received en-doscopy intervention. Through the use of improved traction and normal traction, they were divided into experimental group and control group. Then analyze and compare their clinical data like gender, age, traction line installed perfect time, fixed lesions after hemostatic clip off times, one-time complete resection, enbloc resection rate, bleeding and perforation and other complications and other clinical conditions. Results The improvement time was (53.30 ±12.85) s in experimental group, it was significantly shorter than that in control group (105.00 ± 11.68) s ( = 3.42, <0.05). The experimental group fixed lesions after hemostatic clamp off times were significantly less than that in con-trol group (χ2=2.37, <0.05). Conclusions Using innovative methods, adequate preoperative preparation, the op-erator's tacit understanding of nursing cooperation, close attention to the disease after surgery is the key to achieve the desired results of endoscopic surgery.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Journal of Endoscopy Year: 2016 Type: Article