Your browser doesn't support javascript.
loading
Assessment of Parameters Measured with Volumetric Pulmonary Artery Catheter as Predictors of Fluid Responsiveness in Patients with Coronary Artery Occlusive Disease / 대한흉부외과학회지
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 41-48, 2008.
Article in Korean | WPRIM | ID: wpr-62293
ABSTRACT

BACKGROUND:

Accurate assessment of the preload and the fluid responsiveness is of great importance for optimizing cardiac output, especially in those patients with coronary artery occlusive disease (CAOD). In this study, we evaluated the relationship between the parameters of preload with the changes in the stroke volume index (SVI) after fluid loading in patients who were undergoing coronary artery bypass grafting (CABG). The purpose of this study was to find the predictors of fluid responsiveness in order to assess the feasibility of using certain parameters of preload as a guide to fluid therapy. MATERIAL AND

METHOD:

We studied 96 patients who were undergoing CABG. After induction of anesthesia, the hemodynamic parameters were measured before (T1) and 10 min after volume replacement (T2) by an infusion of 6% hydroxyethyl starch 130/0.4 (10 mL/kg) over 20 min.

RESULT:

The right ventricular end-diastolic volume index (RVEDVI), as well as the central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP), failed to demonstrate significant correlation with the changes in the SVI (%). Only the right ventricular ejection fraction (RVEF) measured at T1 showed significant correlation with the changes of the SVI by linear regression (r=0.272, p=0.017). However, when the area under the curve of receiver operating characteristics (ROC) was evaluated, none of the parameters were over 0.7. The volume-induced increase in the SVI was 10% or greater in 31 patients (responders) and under 10% in 65 patients (non-responders). None of the parameters of preload measured at T1 showed a significant difference between the responders and non-responders, except for the RVEF.

CONCLUSION:

The conventional parameters measured with a volumetric pulmonary artery catheter failed to predict the response of SVI following fluid administration in patients suffering with CAOD.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pulmonary Artery / Stress, Psychological / Stroke Volume / Cardiac Output / Linear Models / Central Venous Pressure / Pulmonary Wedge Pressure / Coronary Artery Bypass / ROC Curve / Hydroxyethyl Starch Derivatives Type of study: Prognostic study Limits: Humans Language: Korean Journal: The Korean Journal of Thoracic and Cardiovascular Surgery Year: 2008 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pulmonary Artery / Stress, Psychological / Stroke Volume / Cardiac Output / Linear Models / Central Venous Pressure / Pulmonary Wedge Pressure / Coronary Artery Bypass / ROC Curve / Hydroxyethyl Starch Derivatives Type of study: Prognostic study Limits: Humans Language: Korean Journal: The Korean Journal of Thoracic and Cardiovascular Surgery Year: 2008 Type: Article