Your browser doesn't support javascript.
loading
Physical and Clinical Evaluation of Hip Spica Cast applied with Three-slab Technique using Fibreglass Material
Malaysian Orthopaedic Journal ; : 17-20, 2016.
Article in English | WPRIM | ID: wpr-626910
ABSTRACT

Introduction:

Hip spica casting is an important component of treatment for developmental dysplasia of the hip (DDH) and popular treatment method for femur fractures in children. Breakage at the hip region is a relatively common problem of this cast. We have developed a three-slab technique of hip spica application using fibreglass as the cast material. The purpose of this review was to evaluate the physical durability of the spica cast and skin complications with its use.

Methodology:

A retrospective review of children with various conditions requiring hip spica immobilisation which was applied using our method. Study duration was from 1st of January 2014 until 31st December 2015. Our main outcomes were cast breakage and skin complications. For children with hip instability, the first cast would be changed after one month, and the second cast about two months later.

Results:

Twenty-one children were included, with an average age of 2.2 years. The most common indication for spica immobilisation was developmental dysplasia of the hip. One child had skin irritation after spica application. No spica breakage was noted.

Conclusion:

This study showed that the three-slab method of hip spica cast application using fibreglass material was durable and safe with low risk of skin complications.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Hip Fractures Language: English Journal: Malaysian Orthopaedic Journal Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Hip Fractures Language: English Journal: Malaysian Orthopaedic Journal Year: 2016 Type: Article