Implantation of lumenless pacing leads at the inter-atrial septum and right ventricular outflow tract with deflectable catheter-sheath / 华中科技大学学报(医学)(英德文版)
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 639-44, 2008.
Article in English | WPRIM | ID: wpr-634977
ABSTRACT
Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation pattern, which results in asynchronous ventricular contraction and relaxation. When pacing from right atrial appendage, the conduction time between two atria will be prolonged, which results in heterogeneity for both depolarization and repolarization. Six patients with Class I indication for permanent pacing were implanted with either single chamber or dual chamber pacemaker. The SelectSecure 3830 4-French (Fr) lumenless lead and the SelectSite C304 8.5-Fr steerable catheter-sheath (Medtronic Inc., USA) were used. Pre-selected pacing sites included inter-atrial septum and right ventricular outflow tract, which were defined by ECG and fluoroscopic criteria. All the implanting procedures were successful without complication. Testing results (mean atrial pacing threshold 0.87 V; mean P wave amplitude 2.28 mV; mean ventricular pacing threshold 0.53V; mean R wave amplitude 8.75 mV) were satisfactory. It is concluded that implantation of a 4-Fr lumenless pacing lead by using a streerable catheter-sheath to achieve inter-atrial septum or right ventricular outflow tract pacing is safe and feasible.
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Pacemaker, Artificial / Sick Sinus Syndrome / Cardiac Pacing, Artificial / Prosthesis Implantation / Electrodes, Implanted / Equipment Safety Language: English Journal: Journal of Huazhong University of Science and Technology (Medical Sciences) Year: 2008 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pacemaker, Artificial / Sick Sinus Syndrome / Cardiac Pacing, Artificial / Prosthesis Implantation / Electrodes, Implanted / Equipment Safety Language: English Journal: Journal of Huazhong University of Science and Technology (Medical Sciences) Year: 2008 Type: Article