Your browser doesn't support javascript.
loading
Comparison of Q-value guide LASIK and standardized LASIK for the treatment of myopia:a meta-analysis / 中华实验眼科杂志
Chinese Journal of Experimental Ophthalmology ; (12): 437-443, 2011.
Article in Chinese | WPRIM | ID: wpr-635514
ABSTRACT
Background Nowadays,customized ablation is widely used in the excimer laser corneal refractive Burgery.And the Q-value guide LASIK is one of the research hotspots. Objective Present study was to evaluate and compare the effectiveness of Q-value guide LASIK and standardized LASIK for myopia.Methods A systematic literature retrieval from 2003 through 2010 was conducted in the MEDLINE,CNKI,Cochrane Library,EMBASE.The literature examine possible difierences in uncorrected visual acuity(UCVA),Q-value,higher order aberrations(HOAs),and spherical equivalent(SE) between Q-value guide LASIK and standardized LASIK for correcting myopia.Statistical analysis was performed using a Review Manager 5.0 software.The data was extracted,and the methodological quality was evaluated by two reviewers independently.The quality of included literature was scored according to the Jadad Scale. Results A total of 14 studies involving 1617 patients(2956 eyes)was included in the meta-analysis.Of these fourteen studies,six studies were randomized trials and the other eight studies were retrospective cohort studies.According to the Jadad Scale,2 studies scored 3 points,and the other 12 studies scored 1~2 points.The results showed that the Q-value guide LASIK group had a better postoperative effectiveness in uncorrective visual acuity(UCVA)(WMD=0.04.95% CI 0.00 to 0.08,P<0.05).Q-value(SMD=-1.52,95% CI -2.23 to-0.81,P=0.00),total HOAs (SMD=-1.63,95% CI-2.57 to-0.69,P<0.05) and spherical-like aberrations ( SMD =-1.49,95% CI-2.22 to-0. 76,P<0. 00) after surgery. However, the number of eyes achieved UCVA≥20/20 ( OR= 1.16,95% CI 0. 61 to 2. 19,P=0. 65) ,coma-like aberrations (SMD=-1. 02,95% CI-0. 36to 0.11,P=0.29) and SE (WMD=0.10,95% CI-0.11 to 0.31,P=0.34) after surgery were comparable.Conclusion The effectiveness of Q-value guide LASIK is superior to standardized LASIK for treatment of myopia.High-quality clinical randomized-controlled study should be performed to further evaluate the comparable outcome of Q-value guide LASIK with standard LASIK.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial / Observational study / Systematic reviews Language: Chinese Journal: Chinese Journal of Experimental Ophthalmology Year: 2011 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial / Observational study / Systematic reviews Language: Chinese Journal: Chinese Journal of Experimental Ophthalmology Year: 2011 Type: Article