Your browser doesn't support javascript.
loading
Preparation of thrombosis-targeted lipid microbubbles and determination of rabbit carotid artery thrombosis by microbubbles ultrasonogaphy / 华中科技大学学报(医学)(英德文版)
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 146-52, 2013.
Article in English | WPRIM | ID: wpr-636165
ABSTRACT
A kind of thrombus-targeted lipid-coated microbubbles were prepared, and the target property of the microbubbles and the effects of different methods detecting thrombosis in vessels were observed. Phospholipid-coated microbubbles were prepared by membrane-hydration method. Thrombus-targeted lipid-coated fluorocarbon microbubbles were labeled with specific fluorescence and then integrated to the thrombus in vivo and ex vivo through an avidin biotin system. The thrombus was immediately observed for the distribution and property of the thrombus-targeted microbubbles under the optical microscope, fluorescence microscope and transmission electron microscope. The carotid thrombosis models were set up in rabbits, and the effects of different methods detecting thrombosis in vessels were observed. The diameter of the phospholipid-coated microbubbles was 0.8-2.5 μm, and even reached nanoscale in some of them. The zeta electric potential was about -11 mV and the concentration was about 1.08×10(10)/mL. Immunofluorescence of rapid frozen sections in vivo and ex vivo showed that massive targeted lipid-coated microbubbles flocked around fresh blood clots and some aggregated within them under the light and fluorescence microscope. The number of aggregated microbubbles ex vivo was greater than that observed in the experiment in vivo, and the fluorescence observed in the experiment ex vivo was stronger than that in the experiment in vivo. The same imaging was observed under the electron microscope. Models of carotid thrombosis in rabbits were established successfully. Effects of detecting thrombosis by means of thrombosis-targeted microbubble ultrasonoraphy and Sono Vue ultrasonography in vessels were more satisfactory than those by Color Doplor Flow Imaging (CDFI), ordinary microbubbles and Three Dimensions-time of flight MR angiography (3D-TOF-MRA) (P<0.01). Compared to ordinary microbubbles ultrasonography, thrombosis-targeted microbubbles ultrasonography had the advantages whenever in imaging quality or in imaging time. Thrombus-targeted phospholipid-coated microbubbles were prepared successfully by membrane-hydration method. They could aggregate rapidly in fresh blood clots and enter deep into the internal part of the thrombus both in vivo and ex vivo, and had the targeted property of strongly conjugating with the thrombus. Compared to other thrombosis detection methods, ultrasonography with thrombosis-targeted microbubbles has obvious advantages in detecting thrombosis in vessels, mainly in non-invasiveness, safety, good image quality, accuracy, and longer imaging time.
Full text: Available Index: WPRIM (Western Pacific) Language: English Journal: Journal of Huazhong University of Science and Technology (Medical Sciences) Year: 2013 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: English Journal: Journal of Huazhong University of Science and Technology (Medical Sciences) Year: 2013 Type: Article