Your browser doesn't support javascript.
loading
Influences of prisms on accommodative response and microfluctuation in emmetropias / 中华实验眼科杂志
Chinese Journal of Experimental Ophthalmology ; (12): 513-517, 2015.
Article in Chinese | WPRIM | ID: wpr-637511
ABSTRACT
Background How to control progression of myopia is a central issue in clinical optometry.Some clinical trials showed that wearing base-in (BI) prism can slow down progression of myopia to certain degree.However,whether BI prism or base-out (BO) prism should be used is worth discussing.Objective This study was to investigate the influences of different prisms on accommodative response and microfluctuation in emmetropias.Methods This clinical trail was approved by Ethic Committee of Peking University People's Hospital.During July in 2014,twenty-two emmetropias of 22 normal volunteers aged 21-27 years were recruited from Peking University People's Hospital under the written informed consent.An open-field infrared refractometer was used to monitor and record pupil diameter and accommodative response under three conditions including non-prism,3△ BI prism,and 3△ BO prism.The accommodative response value was calculated as the difference between reading value and-3.0 D,and root mean square (RMS) of accommodative response value served as amplitude of accommodative microfluctuation.Spectrum of accommodative response was analyzed by one dimension discrete Fourier transformation.The differences of accommodative response value,amplitude of accommodative microfluctuation and pupil diameter among three conditions were compared using repeated one-way ANOVA.Results The accommodative response values were (+0.31±0.78),(+0.51±0.75) and (+0.18±0.72) D under the non-prism,3△BI prism and 3△BO prismconditions,respectively,with a significant difference among them (F =28.078,P =0.000),and compared with the non-prism condition,the accommodative lag of 3△BI prism condition was increased and that of 3△BO prism condition was reduced (P =0.000,0.012).No significant difference was found in the amplitude of accommodative microfluctuation among the three conditions (F=0.062,P =0.879).The percentages of low frequency signal power (0-0.5 Hz)/total power (0-2.5 Hz) was 97.5%,98.3% and 91.4% under the non-prism,3△BI prism and 3△BO prism condition,respectively.The pupil diameter was (5.37-±0.69) mm under the 3 △ BI prism condition,which was larger than (5.07±0.66) mm under the non-prism condition and (5.01 ±0.69) mm under the 3△ BO prism condition (both at P =0.000).Conclusions Compared with wearing 3△ BI prism,wearing 3△ BO prism lessens the accommodative lag,decreases the pupil diameter and reduces the power of low frequency component in accommodative response.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Experimental Ophthalmology Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Experimental Ophthalmology Year: 2015 Type: Article