Your browser doesn't support javascript.
loading
Repeatability of corneal power measurements by Galilei Ⅱ dual Scheimpflug analyzer in post-LASIK eyes / 中华实验眼科杂志
Chinese Journal of Experimental Ophthalmology ; (12): 357-362, 2016.
Article in Chinese | WPRIM | ID: wpr-637691
ABSTRACT
Background The assessment of total corneal power is essential to both the prediction of intraocular lens power before cataract surgery and the diagnosis of corneal ectasia.Objective This study was to access the repeatability of corneal power measurements in post-laser assisted in-situ keratomileusis (LASIK) eyes with GalileiⅡ dual Scheimpflug analyzer.Methods In this cross-sectional study,68 eyes of 36 subjects who received LASIK surgery more than 3 months in Eye Hospital of Wenzhou Medical University were recruited from July to September in 2011.The mean preoperative spherical equivalent diopter was (-4.95±2.08) D in the subjects with the diopter range from-1.75 D to-10.00 D.The parameters of corneal power were measured by Galilei Ⅱ dual Scheimpflug analyzer,including SimK,Ka,Kp,KG and Kray.Three-time consecutive measurements were completed in every examined eye to obtain the data of SimK,Ka,Kp,KG and Kray,respectively.The coefficient of variation (CV),standard deviation (SD),Cronbach α coefficient and intra-class correlation coefficient (ICC) were calculated to evaluate the repeatability.Concordance between the different measurements was assessed using Bland-Altman agreement analysis.This study followed the Helsinki Declaration,all subjects signed informed consent.Results The CVs of three-time measured SimK,Ka,Kp,KG and Kray were 0.24%,0.28%,-0.37%,0.31% and 0.32%,respectively,and the Cronbach α values were >0.9 and the ICCs were >0.982.The Bland-Altman analysis between different measurements showed that the maximum 95% limits of agreement (LoA) were 0.37 D for SimK,0.46 D for Ka,0.09 D for Kp,0.45 D for KG and 0.49 D for Kray,respectively.Conclusions The Galilei Ⅱ dual Scheimpflug analyzer performed high repeatability and concordance on corneal power measurements in post-LASIK eyes.The differences between measuring results are clinically acceptable.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Observational study / Risk factors Language: Chinese Journal: Chinese Journal of Experimental Ophthalmology Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Observational study / Risk factors Language: Chinese Journal: Chinese Journal of Experimental Ophthalmology Year: 2016 Type: Article