Your browser doesn't support javascript.
loading
Clinical study of anterior chamber lens iris clip intraocular lens implantation for high myopia / 国际眼科杂志(Guoji Yanke Zazhi)
International Eye Science ; (12): 1319-1321, 2014.
Article in Chinese | WPRIM | ID: wpr-641989
ABSTRACT
AlM To evaluate the clinical effect of implantation of phakic anterior chamber iris clip intraocular lens in high myopia patients.

METHODS:

Fifty eyes of 28 high myopia patients with anterior chamber phakic Verisyse iris clip intraocular lens implantation were observed. The visual acuity, best corrected visual acuity, intraocular pressure, corneal and anterior chamber inflammation changes were observed after the procedure.

RESULTS:

Fifty eyes of 28 high myopia patients were successfully accepted implantation of phakic anterior chamber iris clip intraocular lens. Visual acuity of all the patients was increased after operation. And one year later, visual acuity of 38 eyes ( 76%) ≥1. 0, 12 eyes (24%) ≥0. 5, best corrected visual acuity of 40 eyes (80%) ≥1. 0, 10 eyes ( 20%) ≥0. 5. ln 22 eyes, the postoperative best corrected visual acuity were reached and exceeded preoperative best corrected visual acuity.CONCLUSlON lmplantation of iris clip intraocular lens in high myopia patients with anterior chamber lens was feasibility and effective.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: International Eye Science Year: 2014 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: International Eye Science Year: 2014 Type: Article