PURPOSE:

The aim of this study was to analyze the clinical symptoms and function and the nerve electrophysiological changes between the pre-operative and long-term post-operative states of patients who underwent surgical treatment with endoscopic release of the carpal tunnel for idiopathic carpal tunnel syndrome. MATERIALS AND

METHODS:

This study was performed in 48 patients and 88 wrists with idiopathic carpal tunnel syndrome. All patients were treated with endoscopic carpal tunnel release using a single portal. The preoperative and the 3 years 5 months long-term postoperative clinical symptoms and function were evaluated using the Boston carpal tunnel questionnaire. The nerve electrophysiological status was evaluated using the Bland grade system.

RESULTS:

When the preoperative Bland grade was 2, 3, 4, 5, and 6, the range of the change of the symptom severity score was 1.38, 1.68, 2.40, 1.61 and 1.28, respectively, and the range of the change of the functional status score was 0.60, 1.34, 1.58, 0.93 and 0.88, respectively, at the long-term follow-up. The clinical symptoms were signifi cantly improved at the fi nal follow-up when the preoperative Bland grade was 2, 3, 4 and 5. The function was signifi cantly improved for all the preoperative Bland grades. On the nerve electrophysiological study, there was statistical improvement of the distal motor latency of the motor nerve and the nerve conduction velocity and amplitude of the sensory nerve. When the preoperative Bland grade was 2, 3, 4, 5 and 6, the extent of improved grade was 0.60, 0.75, 2.17, 2.87 and 4.25, respectively, at the long-term follow-up, and the Bland grade was signifi cantly improved when the preoperative Bland grade was 3, 4, 5 and 6. However, there was no statistical signifi cance between the Bland grade and the clinical state at the long-term follow-up.

CONCLUSION:

The clinical and nerve electrophysiological states were significantly improved at the long-term follow-up after endoscopic carpal tunnel release. When the preoperative Bland grade was 3, 4 and 5, the clinical symptoms, function and the nerve electrophysiological states were signifi cantly improved at the long-term follow-up.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Wrist / Carpal Tunnel Syndrome / Boston / Surveys and Questionnaires / Follow-Up Studies / Neural Conduction Type of study: Diagnostic study / Observational study / Prognostic study Limits: Humans Country/Region as subject: North America Language: Korean Journal: The Journal of the Korean Orthopaedic Association Year: 2011 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Wrist / Carpal Tunnel Syndrome / Boston / Surveys and Questionnaires / Follow-Up Studies / Neural Conduction Type of study: Diagnostic study / Observational study / Prognostic study Limits: Humans Country/Region as subject: North America Language: Korean Journal: The Journal of the Korean Orthopaedic Association Year: 2011 Type: Article