ABSTRACT

PURPOSE:

To compare the results of hydroxyapatite (HA) -coated with porous coated prosthesis for a minimum of five years. MATERIALS AND

METHODS:

We reviewed radiographs of 43 patients in HA group (48 cases) and 44 patient in porous group (48 cases) that followed for a minimum of five years after primary cementless total hip arthroplasty. Average follow up period was 6.2 years in HA group and 6.8 years in porous group.

RESULTS:

Harris hip score was improved to 78.1 point in porous group, 90.9 point in HA group at 6 months after surgery, but at last follwo up, 94 point in HA group, 96 point in porous group, there was no significancy. Thigh pain was noted 22.9% in porous group and 6.3% in HA group at 6 months after surgery (P=0.047) . At last follow up, thigh pain was noted 6.3% and 2.1% respectively. The mean wear of polyethylene liner was 1.36 mm in porous group and 1.72 mm in HA group (P=0.067) . Endosteal bone formation of femoral stem was noted 56.3% of porous group and 91.7% of HA group at one year after surgery, but there was 97% of endosteal bone formation was noted in both group at last follow up. Osteolysis around acetabular cup was noted 8.3% in porous group and 10.4% in HA group, and osteolysis around femoral stem was noted in 20.8%, 37.5% respectively.

CONCLUSION:

The results of HA coated implant was better than that of porous group at initial, but there was no significant differency at last follow up. The difference in rate of osteolysis and polyethylene wear between both groups were not significant at the last follow up. Final acceptance must await follow-up at least of 10 to 15 years in comparison with current hip prostheses.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Osteogenesis / Osteolysis / Prostheses and Implants / Thigh / Follow-Up Studies / Durapatite / Arthroplasty, Replacement, Hip / Polyethylene / Hip / Hip Prosthesis Type of study: Observational study / Prognostic study Limits: Humans Language: Korean Journal: The Journal of the Korean Orthopaedic Association Year: 2000 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Osteogenesis / Osteolysis / Prostheses and Implants / Thigh / Follow-Up Studies / Durapatite / Arthroplasty, Replacement, Hip / Polyethylene / Hip / Hip Prosthesis Type of study: Observational study / Prognostic study Limits: Humans Language: Korean Journal: The Journal of the Korean Orthopaedic Association Year: 2000 Type: Article