Your browser doesn't support javascript.
loading
Radiation Exposure to the Orthopaedic Surgeon during Fracture Surgery / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association ; : 107-113, 2010.
Article in Korean | WPRIM | ID: wpr-653022
ABSTRACT

PURPOSE:

To assess the risk of radiation exposure by measuring the equivalent dose during fracture surgery. MATERIALS AND

METHODS:

Two orthopedic trauma surgeons were enrolled in this study from April to June 2009. The equivalent dose was measured using thermoluminiscent dosimeters placed at the left (in and out of the lead apron).

RESULTS:

The equivalent dose measured from the apron over the 3 month period were 5.22 mSv, 4.34 mSv(outside), and 1.83 mSv and 0.71 mSv(inside). The rate of radiation reduction was 64.9% and 83.6% respectively.

CONCLUSION:

The estimated annual equivalent dose outside the apron was close to or higher than the maximum limit of radiation exposure. These findings highlight the need for surgeons to be more cautious about radiation exposure during fracture management and take active steps to minimize radiation exposure, such as wearing a radio-protective apron.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Orthopedics / Fluoroscopy Language: Korean Journal: The Journal of the Korean Orthopaedic Association Year: 2010 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Orthopedics / Fluoroscopy Language: Korean Journal: The Journal of the Korean Orthopaedic Association Year: 2010 Type: Article