Your browser doesn't support javascript.
loading
Knotting of Pulmonary Artery Catheter During Tricuspid Valve Surgery: A Case Report / 대한구급학회지
The Korean Journal of Critical Care Medicine ; : 45-48, 2012.
Article in Korean | WPRIM | ID: wpr-654533
ABSTRACT
The use of pulmonary artery catheter can be helpful in managing patients after cardiac surgery. Nevertheless, there is a risk of serious complications, such as knotting. A 61 year old man underwent tricuspid valve replacement under cardiopulmonary bypass (CPB). After implantation of a stented tissue valve in the tricuspid valve, repositioning of the catheter was performed. After weaning from CPB, an abnormal pattern of pulmonary artery pressure was suddenly observed on the monitor. Resistance was met when removing the catheter with the balloon deflated, at a 20 cm distance from the tip of the catheter. Chest radiography showed a knot in the catheter within the right brachiocephalic vein. Superior vena cava opened and the distal part of the catheter with the knot was successfully removed.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Organothiophosphorus Compounds / Pulmonary Artery / Thoracic Surgery / Thorax / Tricuspid Valve / Vena Cava, Superior / Weaning / Cardiopulmonary Bypass / Stents / Brachiocephalic Veins Limits: Humans Language: Korean Journal: The Korean Journal of Critical Care Medicine Year: 2012 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Organothiophosphorus Compounds / Pulmonary Artery / Thoracic Surgery / Thorax / Tricuspid Valve / Vena Cava, Superior / Weaning / Cardiopulmonary Bypass / Stents / Brachiocephalic Veins Limits: Humans Language: Korean Journal: The Korean Journal of Critical Care Medicine Year: 2012 Type: Article